This sensor adopts a parallel beam structure, with a metal bellows welded seal and filled with inert gas. It is overload and off-center load resistant. It is widely used in belt scales, hopper scales, electromechanical integration, universal material testing machines, crane scales, and various engineering device force measurement systems.

Overview:

This sensor adopts a parallel beam structure, with a metal bellows welded seal and filled with inert gas. It is overload and off-load resistant. Widely used in belt scales, hopper scales, electromechanical integration, universal testing machines, crane scales and various engineering device force measurement systems.

Features: High measurement accuracy, good stability, and good output symmetry.


Dimensions (In mm. 1mm=0.03937 inches)


Circuit Diagram:

 


Specification:

Item Type

Technical parameters

Measurement Range
Nominal load range

10 ~500kg

Operating Voltage
Power supply

10~12 VDC

Zero Balance

Zero balance

1.0 ± % of rated output

Analog Output
Analog output

2.0±0.01mV/V

Input Impedance

Input resistance (Rlc)

400 ± 20Ω ( ohms )

Output Impedance

Output resistance (Ro)

350 ± ( ohms )

Insulation Resistance

Insulation resistance

5000 M Ω( Mege-Ohms )

Overall Accuracy
Class precision

0.02%FS

Temperature Drift
Effect of temperature

0.02%FS/10℃

Operating Temperature
Operating temperature

-40 ~ +85℃

Safe Overload
Safe Load Limit

200% FS

Safety margin against yielding  
Safety margin against yielding

300% FS

Safety margin against breakage
Safety margin against breakage

500% FS

Material
Material

High-performance alloy steel or (chromium ratio > 15% stainless steel)
High performance alloy steel or (chromium ratio>15% stainless steel)

Protection Type
Protection type

IP67/IP68