Products
PRODUCT CENTER
SM20 corrugated tube load cell
Category:
Overview:
This sensor adopts a parallel beam structure, with a metal bellows welded seal and filled with inert gas. It is overload and off-load resistant. Widely used in belt scales, hopper scales, electromechanical integration, universal testing machines, crane scales and various engineering device force measurement systems.
Features: High measurement accuracy, good stability, and good output symmetry.
Dimensions (In mm. 1mm=0.03937 inches)

Circuit Diagram:

Specification:
|
Item Type |
Technical parameters |
|
Measurement Range |
10 ~500kg |
|
Operating Voltage |
10~12 VDC |
|
Zero Balance Zero balance |
1.0 ± % of rated output |
|
Analog Output |
2.0±0.01mV/V |
|
Input Impedance Input resistance (Rlc) |
400 ± 20Ω ( ohms ) |
|
Output Impedance Output resistance (Ro) |
350 ± 5Ω ( ohms ) |
|
Insulation Resistance Insulation resistance |
≥ 5000 M Ω( Mege-Ohms ) |
|
Overall Accuracy |
0.02%FS |
|
Temperature Drift |
0.02%FS/10℃ |
|
Operating Temperature |
-40 ~ +85℃ |
|
Safe Overload |
200% FS |
|
Safety margin against yielding |
300% FS |
|
Safety margin against breakage |
500% FS |
|
Material |
High-performance alloy steel or (chromium ratio > 15% stainless steel) |
|
Protection Type |
IP67/IP68 |
Keywords:
Previous
Related Applications
undefined
Language