Products
PRODUCT CENTER
SM35-AK-3 load sensor
1. Features
SM35-AK-3 wired load sensor, is designed for pump jack well work diagram testing 。He a load sensor with high anti-interference performance. The product uses standard mv signal output and fully sealed design, can work in high temperature, high cold, high humidity, high radiation and other harsh environments, is currently widely used in pump jack work diagram measurement systems.
Adapts high reliability design for industrial environments, as well as high precision, easy installation, easy maintenance, environmentally friendly and durable features win user recognition, not only in China's Shengli, Daqing, North China, Changqing, Xinjiang, Qinghai and other major oil fields have been promoted and applied, but also in overseas oil companies have been partially applied.
2. Features
Active installation, saving installation and crane costs;
Fully sealed waterproof design, suitable for all-weather use;
High reliability;
Easy and safe operation;
Can be used with other types of wireless data transmission fixed load / displacement transmitter to form a wireless testing system;
Consistent output, fully interchangeable.
Dimensions Dimensions ( In mm. 1mm=0.03937 inches )

Circuit Diagram Circuit Diagram:

Specification Technical parameters:
|
Item Type |
Technical parameters |
|
Measuring range |
0 ~ 150 KN |
|
Sensitivity |
1.7mv/v ± 0.1mV/V |
|
Overall accuracy |
0.5%FS |
|
Input impedance Input impedance impedance |
2000 ± 50 Ω |
|
Output impedance Output impedance impedance impedance |
2000 ± 2 Ω |
|
Zero output Zero balance balance |
≤ 3 %FS |
|
Operating voltage |
10~12 VDC |
|
Temperature drift |
0.5%FS/10℃ |
|
Temperature compensation |
-10~ 65℃ |
|
Operating temperature |
-10 ~ +85℃ |
|
Safe overload |
150% FS |
|
Permanent deformation limit |
300% FS |
|
Material |
High-performance alloy steel or (chromium ratio > 15% stainless steel) |
|
Protection level |
IP68 (IEC60529) |
Keywords:
Previous
Related Applications
undefined