The SM39PWB-CY differential pressure transmitter is used to measure the level, density, pressure, and flow rate of liquids, gases, or steam, and then converts it into a 4mA~20mADC HART current signal output. It can also communicate with a HART handheld terminal for parameter setting and process monitoring.

SM39PWB-CY Differential pressure transmitters are used to measure the level, density, pressure, and flow of liquids, gases, or steam, and then convert them into 4mA ~ 20mADC HART current signal output. It can also communicate with a HART handheld terminal for parameter setting, process monitoring, etc.

Standard Specifications

The range is calibrated based on the standard zero point, using 316L stainless steel diaphragm, filled with silicone oil)

 

  1. Performance Specifications

Calibration reference accuracy (including linearity, hysteresis, and repeatability from zero point )

± 0.075% If TD>10 (TD= maximum range/adjustable range), then: ±(0.0075×TD)%

The square root output accuracy is 1.5 times the above linear reference accuracy.

Environmental Temperature Influence

Range Code

Total influence at -20℃~65℃

Range Code

Total influence at -40℃~-20℃ and 65℃~85℃

A

±(0.45×TD+0.25)%×Span

A

±(0.45×TD+0.25)%×Span

B

±(0.30×TD+0.20)%×Span

B

±(0.30×TD+0.20)%×Span

C/D/F

±(0.20×TD+0.10)%×Span

C/D/F

±(0.20×TD+0.10)%×Span

 

Over-range Influence

 

±0.075%×Span

 

Static Pressure Influence

 

Range Code

Influence

A

±(0.5%Span)/4MPa

B

±(0.3%Span)/16MPa

F/G/H/I/J

±(0.1%Span)/16MPa

 

 

Overpressure Influence

 

Range Code

Influence

A

±0.5%×Span/4MPa

B/C/D/E

±0.2%×Span/16MPa

F/G/H/I/J

±0.1%×Span/16MPa

Long-term Stability

Range Code

Influence

A

±0.5%×Span/1

year

B

±0.2%×Span/1

year

F/G/H/I/J

±0.1%×Span/1

year

Power Supply Influence

±0.001% /10V (12~42V DC), negligible.

  1. Functional Specifications

 

Range and Span

 

Range/Span

kPa

 

A

Range

0~1

Span

-3000~3000

 

B

Range

1~100

Span

-16000~16000

 

C

Range

100~500

Span

-16000~16000

      

D

Range

500~3000

Span

-16000~16000

 

E

Range

3000~4000

Span

-16000~16000

 

F

Range

4000~10000

Span

-16000~16000

 

G

Range

1~100

Span

16000~30000

 

H

Range

100~500

Span

16000~30000

 

I

Range

500~3000

Span

16000~30000

 

J

Range

3000~4000

Span

16000~30000

 

Range Limit

 

It can be adjusted arbitrarily within the upper and lower limits of the range.

 

It is recommended to choose a range code with the lowest possible range ratio to optimize performance characteristics. Zero Point Setting

The zero point and span can be adjusted to any value within the measurement range in the table, as long as: calibrated span ≥ minimum span

 

 

Installation Position Influence

 

Changes in the installation position parallel to the diaphragm surface will not cause zero drift. If the installation position changes more than 90° from the diaphragm surface, a zero offset within the range of <0.4kPa will occur, which can be corrected by adjusting the zero point. There is no span influence.

Output

Two-wire, 4mA~20mADC, optional HART digital communication output, selectable linear or square root output. Output signal limits: I min =3.9mA,I max =20.5mA

Response Time

 

The damping constant of the amplifier component is 0.1s ; the sensor time constant is 0.1s ~1.6s This depends on the measuring range and the range ratio. The additional adjustable time constant is: 0.1s~60s. The effect on non-linear outputs (such as square root function) depends on the function and can be calculated accordingly.

Warm-up time

 

<15s

 

Ambient temperature

 

-40 ℃~85℃

 

-20℃~65℃ with LCD display and fluoroelastomer seal Storage temperature/Transportation temperature

-50 ℃~85℃; -40℃~85℃ with LCD display Working pressure

Rated working pressure is divided into: 16MPa, 25MPa, 40MPa Three levels Static pressure limit

From 3.5kPa absolute pressure to rated pressure, the protection pressure can be more than 1.5 times the rated pressure, applied to both sides of the transmitter simultaneously. Unidirectional overload limit

Unidirectional overload can reach the rated pressure Electromagnetic Compatibility (EMC)

See the "Electromagnetic Compatibility Appendix" on the next page

  1. Installation

 

Power supply and load conditions

 

The power supply voltage is 24V R (Us -12V)/I ma x   k Ω where I ma x =2 3 m A

Maximum power supply voltage: 42VDC

 

Minimum power supply voltage: 12VDC, 15VDC (backlit LCD display) Digital communication load range: 250Ω~600Ω

Electrical connection

 

M20 × 1.5 Cable sealing buckle, terminals are suitable for 0.5 m m 2 ~ 2.5 m m 2  wires. Process connection

The process connection flange has NPT 1/4 and UNF 7/16″ inner threads on both ends.

 

  1. Physical specifications

 

Material

 

Measuring diaphragm: Stainless steel 316L

 

Diaphragm: Stainless steel 316L, Hastelloy C Process flange: Stainless steel 304

Nuts and bolts: Stainless steel (A4) Filling liquid: Silicone oil

Sealing ring: Nitrile rubber NB R ) , fluoroelastomer ( FK M ) , polytetrafluoroethylene PT F E ) Transmitter housing: Aluminum alloy material, epoxy resin coating on the surface

Housing sealing ring: Nitrile rubber (NBR) Nameplate: Stainless steel 304

Weight: 3.3kg (Without: LCD display, mounting bracket, process connection)

 

Housing protection level IP67

 

Electromagnetic Compatibility Appendix

 

Serial number

Test item

Basic standard

Test conditions

Performance level

1

Radiated interference (housing)

GB/T 9254-2008 Table 5

30MHz~1000MHz

Qualified

 

2

Conducted interference

(DC power port)

 

GB/T 9254-2008 Table 1

 

0.15MHz~30MHz

 

Qualified

 

3

 

Electrostatic discharge (ESD) immunity

 

GB/T 17626.2-2006

4kV (contact)

8kV (air)

 

B

 

4

 

Radio frequency electromagnetic field immunity

 

GB/T 17626.3-2006

10V/m

(80MHz~1GHz)

 

A

5

Power frequency magnetic field immunity

GB/T 17626.8-2006

30A/m

A

6

Burst immunity

GB/T 17626.4-2008

2kV(5/50ns,5kHz)

B

 

Note 1: A Performance Level Description: During testing, performance is normal within the limits of the technical specifications.

 

Note 2 : B Performance Level Description: During testing, functionality or performance is temporarily reduced or lost, but can recover automatically, without affecting the actual operating status, storage, or data.