Products
PRODUCT CENTER
SM39PWB-DFL single flange differential pressure transmitter
Category:
- Application
Single Flange Differential Pressure The bellows of the transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It uses a filling liquid such as silicone oil to transmit pressure between it and the transmitter.
SM39PWB-DFL Single Flange Differential Pressure Transmitter Used to measure the level, density, pressure, and flow of liquids, gases, or steam, and then convert it into 4mA ~ 20mADC HART current signal output. It can also communicate with HART handheld communicator for parameter setting, process monitoring, etc. SM39PWB-DFL Single Flange Differential Pressure Transmitter measurement range (before migration) ) is 0…1kPa ~ 2MPa, Single The rated pressure of the flange is: 1.6/4MPa、 6.4MPa 、10MPa、150psi、 300psi or 600psi。
- Working Principle and Structure
SM39PWB-DFL Single Flange Differential Pressure Transmitter Structurally composed of SM39PWB-CY series differential pressure transmitters and welded Single flange assembly . Its working principle is the same as that of SM39PWB-CY series differential pressure transmitters, except that the positive pressure side pressure transmission path is slightly different: the pressure acting on the high-pressure side first passes through Single the diaphragm and filling liquid on the flange, then through the transmitter body, to the high-pressure side of the measuring sensor.
3. Input
Measurement Parameters Differential pressure, level Measurement Range
Lower limit: -100%URL and up (continuously adjustable) Upper limit: to +100%URL (continuously adjustable) Range
Table 1 Range Code and Range Correspondence Table
|
Range Code |
Minimum Range |
Maximum Range |
Rated Pressure (Maximum) |
|
B |
1kPa |
6kPa |
Rated pressure of single flange |
|
C |
4kPa |
40kPa |
|
|
D |
25kPa |
250kPa |
|
|
E |
200kPa |
2MPa |
Table 2 Single Flange Correspondence table between and minimum range
|
Single Flange |
Nominal Diameter |
Minimum Range |
|
Flat type |
DN 50/2 ″ |
10kPa |
|
DN 80/3 ″ |
1kPa |
|
|
DN 4 ″ |
1kPa |
|
|
Insertion type |
DN 50/2 ″ |
16kPa |
|
DN 80/3 ″ |
1kPa |
|
|
DN 4 ″ |
1kPa |
The minimum range of the differential pressure level transmitter should be the larger value of the minimum range in Table 1 and Table 2 . The adjusted range must not be less than the minimum range. The maximum range of the level transmitter should be the minimum value of the maximum range of the transmitter body and Single Flange rated pressure.
- Output
Output Signal
Two-wire, 4mA ~ 20mADC HART output, digital communication, HART protocol loaded on 4mA ~ 20mADC signal.
Output signal limits: I mi n =3. 9 m A , I max =2 0.5m A
- Response Time
The damping constant of the amplifier component is 0.1s ; sensor and Single Flange time constant is 0.2s ~ 2s , depending on the range and range ratio. The additional adjustable time constant is: 0.1s ~ 60s . The additional adjustable time constant is: 0.1s ~ 60s。
- General Conditions
-
- Installation Conditions
Through Single Flange The transmitter can be directly fixed to any position. A good condition is to keep the process flange axis vertical, with positional deviation A correctable zero offset will be generated. The electronic casing can be rotated up to 360° , and a positioning screw can fix it in any position.
-
- Environmental Conditions
Ambient Temperature
Minimum: Depends on the filling liquid Maximum: 85℃
When using LCD display and fluororubber seal -20℃ ~ 65℃ Storage Temperature / Transportation Temperature
Minimum: Depends on the filling liquid Maximum: 85℃
Relative Humidity
0% ~ 100%
Impact Resistance
Acceleration: 50g
Duration: 11ms Vibration Resistance
2g to 500Hz Electromagnetic Compatibility (EMC)
See table on next page 3 Electromagnetic Compatibility Appendix
-
- Process Media Limits
Media Temperature Limit: -30℃ ~ 180℃
Transmitter body pressure limit from 3.5kPa absolute pressure to rated pressure, the protection pressure can be greater than the rated pressure by 1.5 times, applied to both sides of the transmitter simultaneously.
Single Flange Rated Pressure
ANSI Standard 准 :150psi ~ 600psi DIN Standard: PN 1.6MPa ~ PN 10MPa
Unidirectional Overload Limit
The low-pressure side is the rated pressure of the transmitter body, and the high-pressure side is Single Flange rated pressure, and a correctable zero drift may occur. Weight
DN 50/2 ″ Approximately 7 ~ 10kg; DN 80/3 ″ Approximately 8 ~ 11kg; DN 4 ″ Approximately 9 ~ 12kg。 Explosion-proof Performance
NEPSI Explosion-proof certificate: Ex dⅡC T6 NEPSI Intrinsic safety certificate: Ex iaⅡC T4 Permitted operating temperature: -40℃ ~ 65℃
-
- Power Supply and Load Conditions
Power Supply Power Voltage is 24V R≤(Us-12V)/I max kΩ where I max =23 mA
Maximum supply voltage: 42VDC
Minimum supply voltage: 12VDC,15VDC (Backlit LCD display)
Digital communication load range: 230Ω ~ 600Ω Material
Measuring diaphragm: Stainless steel 316L
Diaphragm: Stainless steel 316L , Hastelloy C , Tantalum, FEP 、 PFA 、 PTFE Film-coated flange: Stainless steel 304
Filling liquid: Silicone oil, vegetable oil
Seal: Nitrile rubber ( NB R ) 、Fluororubber( FK M )、 Polytetrafluoroethylene( PTFE )
Transmitter housing: Aluminum alloy material, epoxy resin coating on the surface Housing seal: Nitrile rubber( NBR )
Nameplate: Stainless steel 304 Electrical Connection
M20 × 1.5 Cable sealing clip, terminal block suitable for 0.5 m m 2 ~ 2.5 m m 2 wires.
Process Connection
The transmitter low-pressure side has UNF 7/16 ″ Internal thread. On the high-pressure side of the transmitter Single Flange Compliant ANSI Standard or DIN Standard. Direct installation, refer to the dimensional drawing.
Ingress Protection Rating IP67
Table 3 Electromagnetic Compatibility Appendix
|
Serial Number |
Test Item |
Basic Standard |
Test Conditions |
Performance Level |
|
1 |
Radiated Interference (Enclosure) |
GB/T 9254-2008 Table 5 |
30MHz~1000MHz |
Qualified |
|
2 |
Conducted Interference (DC Power Port) |
GB/T 9254-2008 Table 1 |
0.15MHz~30MHz |
Qualified |
|
3 |
Electrostatic Discharge (ESD) Immunity |
GB/T 17626.2-2006 |
4kV (Contact) 8kV (Air) |
B |
|
4 |
Radio Frequency Electromagnetic Field Immunity |
GB/T 17626.3-2006 |
10V/m (80MHz~1GHz) |
A |
|
5 |
Power Frequency Magnetic Field Immunity |
GB/T 17626.8-2006 |
30A/m |
A |
|
6 |
Burst Immunity Immunity |
GB/T 17626.4-2008 |
2kV (5/50ns, 5kHz) |
B |
|
7 |
Surge Immunity |
GB/T 17626.5-2008 |
1kV (Line-Line) 2kV (Line-Ground) (1.2us/50us) |
B |
|
8 |
RF Field Induced Conducted Interference Immunity |
GB/T 17626.6-2008 |
3V (150kHz~80MHz) |
A |
Note 1: A Performance Level Description: During testing, performance is normal within the limits of the technical specifications.
Note 2: B Performance Level Description: During testing, function or performance is temporarily reduced or lost, but can recover automatically, the actual operating status, storage and data are not changed.
Dimensions
Unit: mm

|
Nominal Diameter |
Rated Pressure |
ΦD |
ΦK |
Φd1 Pluggable |
Φd2 Flat |
Φd3 |
t |
b |
Bolt Required |
|
|
Quantity |
Thread |
|||||||||
|
DN50 |
PN 1.6/4MPa |
165 |
125 |
48.3 |
57 |
102 |
3 +0.5 |
20 |
4 |
M16 |
|
(Sealing surface DIN2526E type) |
PN 6.4MPa |
180 |
135 |
48.3 |
57 |
102 |
3 +0.5 |
26 |
4 |
M20 |
|
(Flange DIN2501) |
PN 10MPa |
195 |
145 |
48.3 |
57 |
102 |
3 +0.5 |
28 |
4 |
M20 |
|
DN80 |
PN 1.6/4MPa |
200 |
160 |
76 |
75 |
138 |
3 +0.5 |
24 |
8 |
M16 |
|
(Sealing surface DIN2526E type) |
PN 6.4MPa |
215 |
170 |
76 |
75 |
138 |
3 +0.5 |
28 |
8 |
M20 |
|
(Flange DIN2501) |
PN 10MPa |
230 |
180 |
76 |
75 |
138 |
3 +0.5 |
32 |
8 |
M24 |
|
DN 2 ″ (ANSI B 16.5 RF type) |
150psi 300psi 600psi |
152.4 165.1 165.1 |
120.6 127.0 127.0 |
48.3 48.3 48.3 |
57 57 57 |
92.1 92.1 92.1 |
3 +0.5 3 +0.5 6.3 5 |
17.4 20.6 31.7 5 |
4 8 8 |
M18 M18 M18 |
|
DN 3 ″ (ANSI B 16.5 RF type) |
150psi 300psi 600psi |
190.5 209.5 209.5 |
152.4 168.3 168.3 |
76 76 76 |
75 75 75 |
127 127 127 |
3 +0.5 3 +0.5 6.3 5 |
22.2 27.0 38.0 5 |
4 8 8 |
M16 M20 M20 |
|
DN 4 ″ |
150psi |
229 |
191 |
89 |
89 |
157 |
3 +0.5 |
30 |
8 |
M18 |
|
(ANSI B 16.5 RF type) |
300psi |
255 |
200 |
89 |
89 |
157 |
3 +0.5 |
32 |
8 |
M18 |
Note: Optional mounting bolts and nuts are available to the user.



Low Pressure End Process Connection Description
- Model and Specification Code Table [1]
-
Fluid Sealing Device
LT-
Single flange, no capillary positive pressure ○ + Side
Process Connection
Nominal Diameter
Sealing Surface Type
Diaphragm/Sealing Surface Material
A
DN50DIN2501
E type DN2526
Stainless Steel 316L
B
DN50DIN2501
E type DN2526
Hastelloy C
C
DN50DIN2501
E type DN2526
Tantalum
H
DN80DIN2501
E type DN2526
Stainless Steel 316L
I
DN80DIN2501
E type DN2526
Hastelloy C
G
DN80DIN2501
E type DN2526
Tantalum
D
DN2″ANSI B 16.5
RF type ANSI B 16.5
Stainless Steel 316L
E
DN2″ANSI B 16.5
RF type ANSI B 16.5
Hastelloy C
F
DN2″ANSI B 16.5
RF type ANSI B 16.5
Tantalum
K
DN3″ANSI B 16.5
RF type ANSI B 16.5
Stainless Steel 316L
L
DN3″ANSI B 16.5
RF type ANSI B 16.5
Hastelloy C
M
DN3″ANSI B 16.5
RF type ANSI B 16.5
Tantalum
N
DN4″ANSI B 16.5
RF type ANSI B 16.5
Stainless Steel 316L
O
DN4″ANSI B 16.5
RF type ANSI B 16.5
Hastelloy C
P
DN4″ANSI B 16.5
RF type ANSI B 16.5
Tantalum
Rated Pressure
Pressure Level
Flange Pressure Standard
1
PN 1.6MPa/4MPa
DIN2501
2
PN 6.4MPa
DIN2501
3
PN 10MPa
DIN2501
6
150psi
ANSI B 16.5
7
300psi
ANSI B 16.5
8
600psi
ANSI B 16.5( Not included DN4″ANSI B 16.5)
Code
Connection Type
F
Flat type
H
Insertion type, 316L stainless steel, Insertion length 50mm
I
Insertion type, 316L stainless steel, Insertion length 100mm
G
Insertion type, 316L stainless steel, Insertion length 150mm
L
Insertion type, Hastelloy C, Insertion length 50mm
M
Insertion type, Hastelloy C, Insertion length 100mm
N
Insertion type, Hastelloy C, Insertion length 150mm
Code Filling liquid
S Silicone oil -30℃~200℃
V Vegetable oil 0℃~250℃
Code Contacting flange diaphragm surface type
N None
1 316L Top Coating FEP (Fluorinated ethylene propylene copolymer )( Temperature ≤180℃)
2 316L Top Coating PFA (Perfluoroalkyl) (Temperature ≤260℃)
3 Diaphragm Paste PTFE Membrane (PTFE membrane)[ 2] (Temperature ≤200℃)
Note 1: In Single Flange When selecting a sealing device, the selection of SM39PWB-CY differential pressure transmitter should be completed first;
Note 2: Diaphragm Paste PTFE Membrane, also F4 diaphragm, can be used for negative pressure measurement, but only for flat type Single Flange 。
Note 3: See the differential pressure transmitter options SM39PWB-CY series transmitter option table;
Note 4: The minimum range of the level transmitter should be the larger value of the minimum range in the table. 1 and Table 2 The adjusted range must not be less than the minimum range. In order to differential pressure transmitter performance is stable, the range ratio should be less than 10∶1 。
Note 5: When the measured pressure or working static pressure < 50kPa( absolute pressure ) ),special remarks should be made, and special processing is required during manufacturing to ensure performance.
Keywords:
Related Applications
undefined
Language