The SM39Y04-L explosion-proof pressure sensor features high precision and high stability: The sensing unit uses BH series foil strain gauges produced with American raw materials and proprietary processing technology from BEAN company in the USA as the force-to-electric conversion element. The transducer (amplifier) uses a high-precision, low-drift instrumentation amplifier as the main amplifier element, with the feedback element specially selected. It has good overall temperature coefficient, few solder joints, small size, and high shock resistance. Integrated temperature compensation technology, the signal is then precisely temperature compensated, amplified and processed into a 4~20mA or 1~5V standard signal. It can interface with DDZⅢ, DDZ-S series instruments, and industrial computers or distributed control systems to achieve automatic measurement and control of the production process. It can be widely used in petroleum, chemical, metallurgical, power, light industry, building materials, scientific research and other fields.

Description Overview

  SM39PCD Electric Pressure Transmitter (Analog Display 4~20mA) is a high-precision, high-stability, multi-parameter, 4 1/2 digit LCD display intelligent pressure measurement product . Precise digital temperature compensation and non-linear correction technology, safe and reliable explosion-proof structure design and standardized signal output, high accuracy, wide range of measurement, suitable for places that need to precisely measure fluid pressure. This product is a two-wire 4~20mADC output transmitter.   It can be widely used in petroleum, chemical, steel, power, building materials, textile, pharmaceutical, food, gas, scientific experiments and military industries, It has been widely used in Daqing, North China, Xinjiang and other oil fields, and has won user recognition for its high precision, high reliability, simple installation, easy maintenance, environmental protection and durability.

 


Dimensions (In mm. 1mm=0.03937 inches)


Circuit Diagram Electrical Wiring

Open the instrument back cover (terminal block surface), see the terminal block, power connection see the figure Among them Power Supply + Power Supply - is Transmitter power supply, signal wiring, terminal 3 spare.

 


Specification Technical Parameters:

1 Measurement Performance 1-130KPa0-3MPa0 -1 0MPa Measurement Range Can be customized according to actual requirements), Range Ratio 100:1 Accuracy Grade: 0.1% 0.05% 0.075%

2 Transmitter Stability: Long-term 15 year ± 0.2%URL

3 Transmitter Response Time 100ms

4 Environmental Indicators: Operating Temperature, -40~+ 85 ℃,Relative Humidity: 5%~95%RH ,No condensation The performance of any component of the instrument cannot be affected by high or low temperature environments

5 Protection Grade: IP67

6 Explosion-proof Mark: Exib II C T6 Gb, Explosion-proof Certificate Number: CE18.1519

7 Power Supply: DC 15-45 V power supply, with rechargeable backup battery, supports power failure 8 h numerical display

8 Output Signal 4~20mA analog signal

9 On-site Display Method Analog display display, after the decimal point 3 bit (can be set);

10 Installation Method: Divided into bracket installation, direct installation;

11 Wetted Material: SUS316L ,Hastelloy, tantalum;’

12 Process Interface: M20*1.5 1/2NPT threaded interface (can be customized according to actual requirements), factory-equipped with a plug.

13 Electrical Interface: M20*1.5 1/2NPT threaded interface (can be customized according to actual customized);

14 Transmitter Housing Material: Low-copper cast aluminum alloy or stainless steel with polyurethane coating.

 

Technical Performance and Function

1 ) Protection Grade: Protection Grade IP67

2 ) Explosion-proof Grade: Exib II C T6 Gb, Explosion-proof Certificate Number: CE18.1519

3 ) Instrument Power Supply: In 12 45V DC power supply range can work normally;

4 ) Electrical Interface: Spare electrical interfaces are equipped with explosion-proof stainless steel sealing plugs.

5 ) Material: Low-copper cast aluminum alloy or stainless steel with polyurethane coating.

6 ) Nameplate and Unit Number Plate and Fasteners are made of stainless steel;

7 ) Transmitter Refresh Time 100 ms with continuously adjustable damping time and in-situ zero setting function.

8 ) Indicator Head : Digital LCD display matched with field transmitter ( or analog ) indicator head, indicating engineering units in accordance with the legal measurement units of the People's Republic of China. Users can choose to display engineering unit values or percentages as needed. In case of failure or damage to the matching indicator head, the output of the intelligent transmitter signal will not be affected; when the instrument fails, the digital LCD head displays the fault code.

9 ) Mounting Bracket : Complete sets of stainless steel mounting brackets and stainless steel mounting accessories are provided.